J-20
J
MF-U
SERIES 176 — High-power Multi-function Measuring Microscopes
Polarized light observation:
Observing only the filtered light that vibrates in one
direction. Used for observing materials with special optical
characteristics, such as mineral and liquid crystal.
Differential interference contrast (DIC) observation:
Effective in detecting fine scratches and steps on the surface
of metal, liquid crystal, and semiconductors.
Dark field (DF) observation:
Observing only the scattered light by shutting down the
directlighttotheobjectives.Thescratchesanddustthat
cannot be viewed in the bright view field can be observed by
this method in high-contrast.
Bright field (BF) observation:
Most common method of observation. Observing directly the
light reflected from the surface of the workpiece.
FEATURES
•Observation with a clear and flare-less erect
image and a wide field of view
•Measuring accuracy that is the highest in its
class (and conforms to JIS B 7153)
•Provenhigh-NAobjectivesfromtheFSoptical
system (long working distance type)
•Integration of metallurgical and measurement
microscope functions provides high-resolution
observation and high-accuracy measurement
solution
•Illumination unit (reflected/transmitted)
selectablefromahigh-intensityLEDor
halogen bulb (required)
•Variable aperture diaphragm (reflected/
transmitted) allows observation measurement
while suppressing light diffraction
•Varietyofstandardizedstagesinsizesupto
400 × 200 mm
•Quick-release mechanism useful for moving
the stage quickly when measuring workpieces
thatarelargeinsizeorquantity
•High-magnicationeyepieceobservationup
to 4000X
•Low-noisedesign
Technical Data
Observation image: Erect image
Optical tube: Siedentoph type (pupil distance
adjustment:51-76mm),1Xtube
lens, Binocular tube (depression: 30˚),
Reticleprojectionmethod,withTV
mount, Optical path ratio (eyepiece/
TV mount: 50/50)
Eyepiece lens: 10X (field No.: 24mm),
Optional: 15X, 20X
Turret (optional): Manual or power
Objective(optional): M/BDPlanApoobjectivefrom1Xto
100X (Refer to page J-36 for more details.)
Transmitted illumination
•Lightsource: Halogenbulb(12V,50W)
•Opticalsystem: Telecentricilluminationwith
adjustableaperturediaphragms
•Functions: Lightintensityadjustable,Non-
steppedbrightnessadjustment
Surface illumination
•Lightsource: Optionalhalogenilluminationunit
(fiber-optic cold light illumination)
•Opticalsystem: Koehlerilluminationwithadjustable
aperture diaphragms
•Functions: Lightintensityadjustable,Non-
steppedbrightnessadjustment
Display unit:
•No.ofaxis: 2axesor3axes
•Resolution: 0.001mm/0.0005mm/0.0001mm/
.0001" / .00005" / .00001"
•Functions: Zero-setting,Directionswitching,
Dataoutput(viaRS-232Cinterface)
Powersupply: 100/110/120/220/240VAC,50/60Hz
Mass:
65.5kg(505C,1010C)/69.5kg(2010C)
/130kg(2017C)/138kg(3017C)/
144kg(4020C)
505C: 50 x 50mm
Selection of XY stage by travel range
1010C: 100 x 100mm
2010C: 200 x 100mm
2017C: 200 x 170mm
4020C: 400 x 200mm
MF-UB3017C
XY stage travel range: 300 x 170mm
(withoptionalturret,objectiveandberillumination)